Automatic air escape valves |
|
AIREX is supplied complete with a shut-off valve (ball valve) that makes it possible to disassemble the valve for cleaning without having to drain the entire system..
Tested by STATENS PROVNINGSANSTALT, Sweden
Certificate No. 7912.96 issued 1979-04-10
Here you can download:
Airex - Service.pdf (0,2Mb)
|
|
AIREX RSK no. 484 5020 |
|
|
|
Technical Data |
|
Max. working pressure |
8 bar |
Burst pressure |
14 bar |
Max. venting capacity |
1 bar/750 litres/h
3 bars/1900 litres/h
6 bars/3400 litres/h |
Max. operating temperature |
120 °C |
Dimensions |
HxD 104/104 mm |
Height mci. shut-offvaive |
140 mm |
Connection |
10, female thre |
Weight md. shut-off vaive |
0,4 kg |
|
|
Tillbaka |
|